AC compressor regulating valve -N280

 

The electric AC compressor regulating valve -N280 is pushed into the compressor and is secured by a spring ring.

The Climatronic control unit -J255 activates the compressor by way of the AC compressor regulating valve -N280. The AC compressor regulating valve -N280 is activated by the Climatronic control unit -J255 such that the temperature of the air downstream of the evaporator reaches the specified value (around 2 to 5°C). In loop control mode the duration of the activation depends on the required cold output, the selected mode of the Climatronic control unit -J255 and the vehicle voltage The activation does, however, last at least long enough for a mean current of 0.3 A to flow. For maximum compressor output, a maximum permissible current of 0.65 A flows via the AC compressor regulating valve -N280.

 

YZNote:

J In measured value block 001 display zone 1 the current flowing via the AC compressor regulating valve -N280 is displayed.

J If no pressure signal is detected by the high-pressure sender -G65, the AC compressor regulating valve -N280 must not be activated.

J Liegt eine Kompressorabschaltbedingung vor, kann das Regelventil für Kompressor der Klimaanlage -N280 (auch während der Stellglieddiagnose) nicht angesteuert werden. In measured value block 002, zone 1, the currently present compressor shut-off conditions are displayed.

J If multiple compressor shut-off conditions apply simultaneously, the conditions are either displayed alternatingly or only the shut-off condition assigned the highest priority by the Climatronic control unit -J255 is displayed.

J Under certain conditions, residual moisture in the refrigerant circuit may cause ice to form on the AC compressor regulating valve -N280 (and on the expansion valve). Such ice formation impairs compressor control; the evaporator is cooled excessively and ices up. Icing-up of the evaporator may give rise to various complaints.

A Air conditioner; Rep.Gr. 87; Checking AC compressor regulating valve -N280

 A Current flow diagram

 