Actuators

Logic of naming actuators in VW-group is simple it contains "N" + actuator number. The actuator number is unique. Here you can find fitting location, connectors and some basic information about actuators.

To our mind, actuators information is reference, so there is only simple search by number.

N

Audi R8 42 (2007- )
Audi A8 4E (2002 -)
Audi A6 4F (2005- )
Audi Q7 4L (2007- )
Audi TT 8J (2006- )
Audi A4 8K (2008-)
Audi A3 8P (2003- )
Audi Q5 8R (2009- )
N280_8R_87_____1_0108_21_Funktion
N280_8R_87_____1_0108_21_Sollwerte

Checking AC compressor regulating valve -N280

 

Display group number 001

 

Display zone 1

Specified current to activate AC compressor regulating valve -N280- in A (Amperes)

- The specified current is calculated by the Climatronic control unit -J255. The request is sent over the data bus system to the onboard power supply control unit -J519.

- The maximum control current consumption depends on the design of the Climatronic control unit -J255

- The AC compressor regulating valve -N280- is activated by the onboard power supply control unit -J519 - see Current Flow Diagrams, Electrical Fault-finding and Fitting Locations

J Activation of the AC compressor regulating valve -N280- is indicated in the measured value block of the onboard power supply control unit -J519- (address word 09 measured value block 34).

 

 Display zone 2

Actual current flowing via AC compressor regulating valve -N280-  in A (Amperes)

- The actual current is measured by the onboard power supply control unit -J519 and sent over the data bus system to the Climatronic control unit -J255.

J Activation of the AC compressor regulating valve -N280- is indicated in the measured value block of the onboard power supply control unit -J519- (address word 09 measured value block 34).

 

Display zone 3

Display zone currently not used.

 

Display zone 4

Pressure in refrigerant circuit in bar.

- The measured value of the refrigerant pressure and temperature sender -G395 is evaluated by the onboard power supply control unit -J519 and sent over the data bus system to the Climatronic control unit -J255 (see Current Flow Diagrams, Electrical Fault-finding and Fitting Locations).

J The measured values of the refrigerant pressure and temperature sender -G395- are indicated in the measured value block of the onboard power supply control unit -J519- (address word 09 measured value block 23). The displayed temperature value is currently not used by the Climatronic control unit -J255-.

 

Display group number 002

 

Display zone 1

Current valid compressor shut-off condition.

- If the readout is 0 the compressor is on.

 

Display zone 2 … 4

Last, last-but-one and third-last compressor shut-off condition.

 

Breakdown of compressor shut-off conditions in display group 002:

Compressor off if:

J Readout = "1"

Pressure in refrigerant circuit has been or is too high

J Readout = "2"

Basic setting not executed

J Readout = "3"

Pressure in refrigerant circuit too low

J Readout = "4"

Engine on for less than 2 sec

J Readout = "5"

Engine speed less than 300 rpm

J Readout = "6"

The compressor has been switched off by the "Econ" function

J Readout = "7"

The compressor has been switched off by the "OFF" function

J Readout = "8"

The measured ambient temperature was below + 2 °C, is still below + 5 °C and there is no request for recirculated air mode (or below - 2 °C / + 2 ° C if a request for recirculated air mode

has occurred) 

J Readout = "9"

Readout not planned at present

J Readout = "10"

Vehicle voltage below 9.5 V

J Readout "11"

Coolant temperature too high, currently above 118 °C

J Readout = "12"

Load reduction by engine control unit

J Readout = "13"

Pressure sensor defective

J Readout = "14"

Gateway message failed

J Readout = "15"

pressure in refrigerant circuit is or has been too high more than 30 times

J Readout = "16"

Measured temperature downstream of evaporator has been below 0 °C for over a minute

J Readout = "17"

Measured temperature downstream of evaporator is below -5 °C

J Readout = "18"

External sensor defective

J Readout = "19"

Auxiliary heater

J Readout = "20"

Readout not planned at present

J Readout = "21"

Ambient temperature between -8 °C or -5° C and 2 °C or 5 °C but no request for recirculated air

J Readout = "22"

Ambient temperature between -8 °C or -5° C and 2 °C or 5 °C and request for recirculated air, but interior temperature below 8 °C

J Readout = "23"

Radiator fan pre-activation

J Readout = "24"

Compressor shut-off by energy management

J Readout = "25"

Load shedding

J Readout = "26"

Compressor shut-off by energy management

J Readout = "27"

Basic setting 3 not yet performed

 